<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>40408</ErrorNumber>
<ErrorFamily>Media Handler</ErrorFamily>
<ErrorMessage>
MDH: Please close plate cover
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Autoloader</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Either the plate cover door is open or there is a problem with the sensor.
</text></DescriptionText>
<DescriptionText><text>
This error is reported if the plate cover door is open and either the picker or
the plate separator arms attempt to move.
</text></DescriptionText>
<DescriptionText><text>
The sensor status may be checked by using the PICKER command. The sensor status
should read TRUE if the plate cover sensor is activated.
</text></DescriptionText>
<DescriptionText><text>
With the key-switch in the normal position, the picker cannot move unless this sensor
indicates that the door is closed.  Disabling the sensor through firmware does not
allow the picker to move.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Close the hinged plate cover door and select the RESUME button on the
workstation dialog box.  Call the Response Centre if the problem persists.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The plate cover door is probably open.
</Cause>
<Cause>
The plate cover door may be obstructed by something.
</Cause>
<Cause>
The plate cover door sensors may be damaged, or not adjusted correctly.
</Cause>
<Cause>
The wiring to the sensors may be disconnected or damaged.
</Cause>
<LastModified>
23-NOV-2001
Created.
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:26 2008 PST
</Updated>
<Links>
</Links>
</Error>